Actin, Alpha Skeletal Muscle

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 CYS-10   ASP-11  7.4 6.4 14.2 -12.2 8.9 8.9 14.3
 ASP-11   ASN-12  6.0 5.5 31.8 -64.9 65.2 83.0 -143.0
 ASN-12   GLY-13  9.1 8.8 34.2 -38.4 28.2 1.2 -19.5

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 LYS-18   ALA-19  6.3 7.3 -34.5 39.5 124.7 132.7 8.8
 ALA-19   GLY-20  6.0 6.9 -12.2 39.2 138.8 137.1 154.6
 GLY-20   PHE-21  3.9 4.2 3.0 6.4 69.8 59.5 36.4

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ASP-24   ASP-25  3.1 2.7 -11.4 25.7 145.7 151.3 91.7
 ASP-25   ALA-26  5.6 5.0 -57.3 9.5 132.3 141.4 -265.6
 ALA-26   PRO-27  3.9 4.1 18.6 3.7 104.5 117.1 92.8

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ALA-29   VAL-30  8.1 9.3 -12.9 10.4 8.4 10.1 21.1
 VAL-30   PHE-31  9.4 10.5 47.6 -42.3 101.4 102.9 60.8
 PHE-31   PRO-32  12.8 13.8 -11.4 -13.7 27.6 15.8 177.6

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLN-137   ALA-138  5.1 4.8 -32.1 5.8 109.1 102.8 57.8
 ALA-138   VAL-139  4.7 4.3 6.7 -17.0 117.3 109.5 6.4
 VAL-139   LEU-140  8.1 7.8 22.2 0.7 153.1 159.2 -143.4

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 TRP-340   ILE-341  1.1 0.6 -12.9 -3.6 119.8 116.5 -30.4
 ILE-341   GLY-342  3.5 3.9 11.9 -10.7 105.2 106.0 -14.1
 GLY-342   GLY-343  5.8 6.1 15.4 -15.7 58.3 63.9 20.8

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees