Serum Albumin

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PHE-376   THR-377  9.7 10.0 -5.0 -4.8 92.0 94.7 33.5
 THR-377   PRO-378  10.1 10.5 1.7 7.9 61.2 60.4 94.3
 PRO-378   LEU-379  7.6 8.1 -8.9 5.1 62.5 61.0 -106.2
 LEU-379   VAL-380  5.0 5.3 6.5 -11.9 139.1 140.2 116.4
 VAL-380   GLU-381  5.7 6.0 0.1 5.6 71.7 70.8 -51.3
 GLU-381   GLU-382  7.2 7.8 7.1 -9.8 69.4 72.4 -21.2
 GLU-382   PRO-383  4.9 5.3 -6.3 -6.4 46.1 51.6 134.4
 PRO-383   LYS-384  4.4 4.8 6.5 0.0 110.3 116.5 -23.8
 LYS-384   SER-385  7.7 7.8 -11.8 -5.6 125.1 119.0 -227.8
 SER-385   LEU-386  9.4 10.0 15.3 1.6 93.0 81.8 128.3
 LEU-386   VAL-387  9.0 9.0 0.9 -4.7 143.5 143.9 51.2

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 VAL-432   GLY-433  15.2 14.9 0.7 2.6 94.3 97.9 -30.3
 GLY-433   SER-434  16.3 15.6 -3.9 12.3 146.2 145.5 91.6
 SER-434   ARG-435  18.4 18.0 -6.9 -5.0 137.9 136.8 -60.4

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ASN-457   ARG-458  15.8 15.4 -2.9 6.4 87.6 85.2 -3.5
 ARG-458   LEU-459  18.8 18.3 3.7 -5.7 22.6 20.4 -0.3
 LEU-459   CYS-460  19.1 18.4 5.9 -12.8 67.3 66.8 -45.9
 CYS-460   VAL-461  18.9 18.5 4.3 -7.3 114.7 115.3 24.8
 VAL-461   LEU-462  21.6 21.3 5.8 14.7 63.5 67.8 122.6
 LEU-462   HIS-463  23.8 23.2 0.7 0.9 17.9 17.9 57.8
 HIS-463   GLU-464  23.0 22.5 -12.3 8.1 97.2 100.7 -26.9
 GLU-464   LYS-465  24.1 24.0 -11.5 -5.4 82.0 80.6 48.8
 LYS-465   THR-466  27.5 27.0 -1.5 6.6 155.0 141.6 203.3
 THR-466   PRO-467  28.0 27.4 2.3 -20.4 48.3 47.5 -296.6
 PRO-467   VAL-468  25.2 25.0 16.5 -5.3 31.7 35.8 161.5
 VAL-468   SER-469  24.6 24.1 9.4 -22.5 55.6 51.4 -194.9
 SER-469   GLU-470  20.9 20.8 3.8 7.3 95.1 95.4 -60.2
 GLU-470   LYS-471  19.3 19.3 7.3 -13.9 110.6 108.5 127.2
 LYS-471   ILE-472  15.7 15.8 7.7 -6.0 177.7 171.0 -58.2
 ILE-472   THR-473  16.8 16.5 0.8 4.1 112.8 109.1 -63.6
 THR-473   LYS-474  18.6 18.5 -2.1 -0.2 90.2 90.8 5.4
 LYS-474   CYS-475  15.8 15.7 3.5 7.6 138.4 132.7 -79.8
 CYS-475   CYS-476  13.3 13.0 4.4 -8.2 153.4 150.1 64.9
 CYS-476   THR-477  15.8 15.5 11.7 26.7 99.3 97.1 -269.9

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PHE-487   SER-488  9.9 9.8 3.7 -6.3 68.2 69.6 42.1
 SER-488   ALA-489  7.8 7.8 9.6 -17.0 6.7 5.5 -111.5
 ALA-489   LEU-490  6.9 7.1 -2.5 7.3 121.4 121.1 -7.6

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees