Nitric Oxide Synthase

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ASP-125   LYS-126  11.7 11.8 9.0 -11.8 62.5 64.7 -65.0
 LYS-126   PRO-127  13.6 13.5 -0.4 -5.8 151.1 148.6 -111.7
 PRO-127   THR-128  12.5 12.2 -20.5 14.6 130.4 129.3 -167.9
 THR-128   PRO-129  12.6 12.3 -3.1 -3.3 116.2 120.6 -28.4
 PRO-129   LEU-130  16.1 15.8 15.4 13.7 21.7 9.0 720.4
 LEU-130   GLU-131  16.5 16.9 -18.6 5.6 140.6 131.8 -339.0
 GLU-131   GLU-132  18.1 18.2 -12.0 -0.9 104.5 105.0 -131.9
 GLU-132   LEU-133  15.0 15.2 9.9 -5.7 70.7 72.7 28.1
 LEU-133   LEU-134  12.4 12.5 5.3 -4.2 17.6 21.3 90.9
 LEU-134   PRO-135  13.9 13.9 -0.1 -0.2 137.5 140.5 -94.5
 PRO-135   HIS-136  13.6 13.8 2.7 -2.6 90.7 88.0 34.4
 HIS-136   ALA-137  10.2 10.4 -4.3 5.7 109.0 109.3 -35.7
 HIS-136   ALA-137  10.2 10.4 -4.3 5.7 109.0 109.3 -35.7

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 HIS-136   ALA-137  10.2 10.4 -4.3 5.7 109.0 109.3 -35.7
 HIS-136   ALA-137  10.2 10.4 -4.3 5.7 109.0 109.3 -35.7
 ALA-137   ILE-138  9.2 9.1 10.5 -11.2 4.4 5.7 -39.6
 ILE-138   GLU-139  10.5 10.4 6.4 1.3 63.0 61.5 109.0

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ASP-178   GLU-179  9.1 9.1 0.7 1.3 86.8 87.4 97.8
 GLU-179   LEU-180  5.7 5.7 -2.5 -4.0 137.6 136.4 -80.3
 LEU-180   ILE-181  5.7 5.5 4.6 -1.7 106.9 106.5 39.8

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 LEU-351   GLU-352  3.6 3.7 1.4 -4.2 77.4 79.3 63.4
 GLU-352   VAL-353  3.8 3.8 -9.6 13.4 161.6 162.8 24.9
 VAL-353   GLY-354  2.9 2.8 -3.7 10.3 97.2 96.7 82.3

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLY-355   LEU-356  8.0 7.8 2.4 12.0 34.7 38.0 203.7
 LEU-356   GLU-357  5.4 5.5 -14.3 22.4 114.6 117.7 214.2
 GLU-357   PHE-358  3.0 3.3 -0.4 -3.6 125.0 116.8 -48.0

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees