Recoverin (Calcium Sensor In Vision)

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PHE-158   PHE-159  10.6 10.5 9.5 -15.8 116.7 116.0 29.9
 PHE-159   GLY-160  7.0 6.9 6.2 -10.3 153.7 150.6 82.0
 GLY-160   LYS-161  8.6 8.7 2.8 3.0 92.4 95.6 -32.4

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 LEU-167   THR-168  3.7 3.7 2.2 0.9 105.0 106.1 -47.8
 THR-168   GLU-169  3.8 3.6 -0.3 -1.8 54.4 52.0 32.0
 GLU-169   LYS-170  4.5 4.5 -7.4 8.5 121.0 121.7 58.4
 LYS-170   GLU-171  5.5 5.5 -3.2 -2.1 93.8 93.5 12.2
 GLU-171   PHE-172  2.8 2.9 0.9 3.4 150.8 151.1 -135.8
 PHE-172   ILE-173  2.6 2.5 -2.5 4.4 73.7 73.7 131.7
 PHE-172   ILE-173  2.6 2.5 -2.5 4.4 73.7 73.7 131.7

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PHE-172   ILE-173  2.6 2.5 -2.5 4.4 73.7 73.7 131.7
 PHE-172   ILE-173  2.6 2.5 -2.5 4.4 73.7 73.7 131.7
 ILE-173   GLU-174  6.2 6.1 -3.5 2.2 125.8 125.1 -34.4
 GLU-174   GLY-175  7.5 7.5 -5.6 0.8 78.0 75.9 35.8
 GLY-175   THR-176  7.3 7.4 10.8 -5.4 151.6 156.3 -125.3

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLN-187   PHE-188  8.2 8.2 -2.2 2.6 44.6 42.6 60.1
 PHE-188   GLU-189  5.9 5.9 6.4 -10.0 160.4 157.5 108.5
 GLU-189   PRO-190  7.2 7.5 -5.8 2.0 66.9 66.4 41.6

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees