Endo-1,4-Beta-D-Xylanase

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ALA-299   LEU-300  7.7 7.8 3.2 1.7 120.5 117.3 -91.4
 LEU-300   ASN-301  9.7 9.8 -4.2 6.2 28.8 27.3 -55.0
 ASN-301   GLY-302  7.5 7.6 -14.8 1.8 46.1 45.8 252.0
 GLY-302   GLY-303  7.7 7.8 -146.0 -149.5 112.9 99.3 986.8
 GLY-313   GLN-314  16.6 16.7 12.9 -10.5 83.9 83.8 -6.9
 GLN-314   ILE-315  17.0 16.9 4.2 -10.3 98.2 98.9 37.0
 ILE-315   LYS-316  14.9 14.9 -2.1 -8.6 60.5 66.5 342.0
 LYS-316   GLY-317  16.2 16.5 6.5 -1.0 99.0 105.2 -81.6
 GLY-317   VAL-318  16.6 16.5 1.7 -2.7 169.3 172.0 50.8
 VAL-318   GLY-319  15.5 15.7 4.2 4.4 111.2 106.6 -119.0

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 TYR-352   THR-353  10.2 10.2 6.7 -8.1 117.2 116.0 88.0
 THR-353   ASP-354  9.9 9.8 2.0 3.1 89.0 89.8 -32.4
 ASP-354   ALA-355  8.4 8.2 -0.3 -1.7 51.2 53.8 46.7
 ALA-355   GLY-356  6.2 6.0 0.2 -3.4 113.1 114.9 29.8
 ALA-355   GLY-356  6.2 6.0 0.2 -3.4 113.1 114.9 29.8

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ALA-355   GLY-356  6.2 6.0 0.2 -3.4 113.1 114.9 29.8
 ALA-355   GLY-356  6.2 6.0 0.2 -3.4 113.1 114.9 29.8
 GLY-356   GLU-357  5.3 5.2 1.9 2.5 79.6 77.6 -38.8
 GLU-357   LEU-358  8.6 8.6 -1.7 -1.8 38.6 38.9 116.2

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLN-388   LYS-389  9.1 9.2 -1.9 3.0 130.3 130.7 82.9
 LYS-389   TRP-390  6.0 6.1 -3.0 -0.4 144.7 145.8 -122.1
 TRP-390   ARG-391  6.1 6.2 -6.8 6.8 129.9 129.9 39.1
 ARG-391   LEU-392  4.1 4.0 4.5 -5.5 26.5 27.6 -6.7
 LEU-392   ASN-393  4.8 4.7 -6.1 6.5 130.1 134.1 24.8
 ASN-393   SER-394  4.1 4.2 1.5 -5.0 20.2 21.7 -162.9
 SER-394   ASP-395  2.9 3.0 2.1 -0.4 55.4 56.3 123.6

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 VAL-399   GLY-400  8.8 8.8 0.1 -2.1 22.8 23.7 -42.5
 GLY-400   VAL-401  9.0 9.0 -4.9 7.0 113.7 116.2 70.4
 VAL-401   GLN-402  6.4 6.4 -1.8 1.3 135.4 134.9 5.6

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees