Phosphoserine Phosphatase (Psp)

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLY-136   GLU-137  9.0 8.8 159.4 22.2 145.6 134.7 -213.9
 GLU-137   VAL-138  9.6 5.6 142.4 51.2 106.2 99.4 154.3
 VAL-138   LEU-139  6.5 3.1 123.4 54.8 112.6 64.7 44.8

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 LYS-140   GLU-141  5.4 2.6 144.5 1.7 76.7 104.0 5.8
 GLU-141   ASN-142  4.3 4.1 8.2 42.5 95.5 169.9 -51.2
 ASN-142   ALA-143  8.1 3.5 -64.2 1.2 30.6 79.6 81.0

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ILE-157   ASN-158  26.4 16.3 -164.6 2.4 20.6 98.4 182.6
 ASN-158   LEU-159  26.4 16.7 -154.9 -30.5 87.8 70.6 61.3
 LEU-159   GLU-160  23.1 20.2 20.0 -20.4 92.1 167.5 6.7
 GLU-160   ASP-161  25.4 19.0 80.9 52.0 23.1 95.6 -227.6

Downloading Image