Fumarate Reductase Flavoprotein Subunit

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 TYR-231   HIS-232  4.7 4.3 -6.5 5.7 95.1 92.2 7.3
 HIS-232   PRO-233  4.1 3.9 -6.4 -0.9 114.1 110.7 49.4
 PRO-233   THR-234  3.6 3.4 -0.3 11.8 55.3 59.2 46.9

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLY-235   LEU-236  4.6 4.4 -0.1 -4.8 101.2 103.6 10.7
 LEU-236   PRO-237  6.9 6.7 -15.2 1.4 88.8 94.0 4.8
 PRO-237   GLY-238  7.9 7.9 6.7 2.9 23.6 16.7 85.8
 GLY-238   SER-239  7.6 8.2 7.4 -11.1 123.1 122.8 37.0
 GLY-238   SER-239  7.6 8.2 7.4 -11.1 123.1 122.8 37.0

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 GLY-238   SER-239  7.6 8.2 7.4 -11.1 123.1 122.8 37.0
 GLY-238   SER-239  7.6 8.2 7.4 -11.1 123.1 122.8 37.0
 SER-239   GLY-240  5.0 5.2 -21.0 22.6 122.1 119.1 83.2
 GLY-240   ILE-241  2.8 2.5 -26.5 25.2 79.2 81.1 73.9

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PRO-352   THR-353  1.7 1.7 -17.4 31.6 141.0 140.8 37.8
 THR-353   ALA-354  0.9 1.2 -4.0 10.4 92.9 86.4 -45.8
 ALA-354   HIS-355  4.3 4.4 -3.4 4.0 126.8 125.4 41.8

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees