Phosphoglucose Isomerase

(All numbering and residues are taken from first PDB file)

Bending Residue Dihedral Analysis

Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 LEU-204   PHE-205  7.9 7.9 -1.3 0.6 120.9 122.4 -11.3
 PHE-205   ILE-206  4.8 4.9 0.4 -4.3 119.5 120.1 7.3
 ILE-206   ILE-207  1.4 1.4 -9.6 11.6 137.0 135.2 25.4

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 LYS-225   ASP-226  8.6 8.6 -0.8 -3.2 51.2 48.8 37.1
 ASP-226   TRP-227  10.6 10.4 9.3 -8.5 84.6 89.6 3.3
 TRP-227   PHE-228  11.1 10.8 -0.2 -3.9 143.3 141.4 -48.3

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 PHE-242   VAL-243  6.4 6.5 -2.4 -2.4 44.7 43.0 70.9
 VAL-243   ALA-244  4.3 4.3 -0.1 -8.8 117.4 116.8 -50.3
 ALA-244   LEU-245  4.3 4.1 4.8 -10.0 127.3 126.6 24.4

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees


Residue
i
Residue
i+1
Distance of hinge axis to residue i in conformer 1
(A)
Distance of hinge axis to residue i in conformer 2
(A)
Change in psi (i)
(deg)
Change in phi (i+1)
(deg)
Angle of psi(i) axis to hinge axis conformer 1
(deg)
Angle of psi(i) axis to hinge axis conformer 2
(deg)
Percentage Progress
 ASP-258   PRO-259  11.2 11.3 6.3 7.3 68.4 59.0 116.2
 PRO-259   GLN-260  11.3 11.7 -11.1 -19.0 148.4 139.2 -293.9
 GLN-260   ASN-261  9.9 9.6 25.3 -5.1 101.9 108.6 26.4
 ASN-261   MET-262  6.7 6.9 -5.9 -8.5 55.0 60.3 128.5

Downloading Image

Graph shows rotational transition at bending residues and can be used to identify hinge bending residues.
Probably only informative for interdomain rotations greater than 20 degrees